Operating data for aluminum -8 – Hypertherm PAC500 Water Injection Plasma Cutting System User Manual

Page 39

Advertising
background image

4-8

PAC500

Instruction Manual

4

OPERATION

Operating Data for Aluminum

Material

Thickness

Inches

mm

Nozzle and

Swirl ring

Size

inches

Gas Type and

Flowmeter

Setting

%

Injection

Water Flow

Setting

%

Torch to

Work

Distance

Inches

mm

Arc

Voltage

Setting

Volts

Arc

Current

Setting

Amperes

Travel

Speed

ipm

mm/min

.035

1

1/8

3

125

250

540

13715

.075

2

.120

N

2

30

85

1/8

3

130

250

360

9145

1/8

3

3/16

5

135

260

240

6095

1/4

6

Maximum current for this nozzle is 260 amp.

1/4

6

145

260

180

4570

1/8

3

1/4

6

140

300

240

6095

1/4

6

1/4

6

145

325

180

4570

3/8

10

.166

N

2

45

75

1/4

6

150

350

150

3810

1/2

13

1/4

6

155

375

120

3050

3/4

19 Maximum current for this nozzle is 400 amp.

5/16

8

160

400

60

1525

1

25

3/8

10

165

400

35

915

1

25

3/8

10

165

550

70

1830

1-1/2

38

.187

N

2

45

75

3/8

10

170

550

35

915

2

50 Maximum current for this nozzle is 600 amp.

3/8

10

170

600

25

610

2

50

.220

N

2

70

100

1/2

13

190

700

30

760

3

75 Maximum current for this nozzle is 750 amp.

5/8

16

200

750

15

355

Use the brass tapered retaining cap part no. 020034 above 400 amperes.

For cutting thicker plate refer to the chart Operating Data for High Current Cutting on page 4-10.