Water tube -4 – Hypertherm PAC500 Water Injection Plasma Cutting System User Manual

Page 45

Advertising
background image

5-4

PAC500

Instruction Manual

4

MAINTENANCE

Changing the Water Tube

WARNING

Always disconnect the power supply

from the main power source before

inspecting or changing the torch parts.

Water Tube

If the water tube is improperly installed, loose or bent, you may experience some difficulties such as: short
electrode life, flow switch interlock shutting down the system, or humming or rattling sound coming from the torch.
If you suspect a problem with the water tube, you may need to replace it.

1. Remove all consumables from torch (see above).

2. Look for any damage or bends in the water tube. The water tube should be recessed from the face of the torch

head by about 11/32" (8.5 mm). Check for tightness.

3. Remove and replace the water tube (120035) by using the water tube wrench (027347) supplied by

Hypertherm. When installing water tube, do not overtighten! Snug down by hand only.

Retaining Caps

Nozzles

Electrode Water Tube

Current Ring

Swirl