Page 1b-4

THC-2 Torch Height Control

INSTALLATION - MAX200

INSTALL INTERCONNECT CABLE TO MAX200

Strain Relief

R4

TB4

TB3

Figure 1b-3 Inside Rear of MAX200 Power Supply

1.

Connect the interface cable to RECP2 on the THC-2 module.

2.

Loosen the adjustable strain relief on the rear of the MAX200 power supply - Fig. 1b-3.

3.

Thread the other end of the interface cable through this strain relief and make
connections to TB4, TB3 (Fig. 1b-3) and voltage divider as shown in the Figure 1b-4
wiring diagram. Note: Push wires labeled 42 and 70 through the center wall feed-thru to
get to voltage divider.

4.

Connect the white wire from the voltage divider to location #45 on R4 which is located on
the left rear wall of the MAX200 power supply - Fig. 1b-4.

This completes installation of the THC-2 to the MAX200. See Section 2 for operation
instructions.