INSTALLATIONS

10

MI946F User’s Manual


JP2: LCD Panel Power Selection

JP2

LCD Panel Power

3.3V

5V

JP4, JP5, JP6: RS232/422/485 (COM2) Selection
COM1 is fixed for RS-232 use only.
COM2 is selectable for RS232, RS-422 and RS-485.
The following table describes the jumper settings for COM2 selection.


COM2

Function

RS-232

RS-422

RS-485


Jumper

Setting

(pin closed)

JP4:

1-2

JP5:

3-5 & 4-6

JP6:

3-5 & 4-6

JP4:

3-4

JP5:

1-3 & 2-4

JP6:

1-3 & 2-4

JP4:

5-6

JP5:

1-3 & 2-4

JP6:

1-3 & 2-4