JP1, JP2, JP3: RS232/RS422/RS485 (COM2) Selection



COM2

Function

RS-232

RS-422

RS-485


Jumper

Setting

(Pin closed)

JP1:

1-2

JP2

3-5&4-6

JP3:

3-5&4-6

JP1:

3-4

JP2:

1-3&2-4

JP3:

1-3&2-4

JP1:

5-6

JP2:

1-3&2-4

JP3:

1-3 & 2-4


JP4: COM2 RS232 RI/+5V/+12V Power Setting


JP4

Setting

Function

Pin 1-2

Short/Closed

+12V

Pin 3-4

Short/Closed

RI

Pin 5-6

Short/Closed

+5V

Note: The suggested setting is RI, with maximum current lower than 1A.

JP5: COM1 RS232 RI/+5V/+12V Power Setting


JP5

Setting

Function

Pin 1-2

Short/Closed

+12V

Pin 3-4

Short/Closed

RI

Pin 5-6

Short/Closed

+5V

Note: The suggested setting is RI, with maximum current lower than 1A.

JP7: ME TLS DISABLE/ENABLE (Factory use only)

JP7

ME TLS Disable/Enable

Open

Disabled

(Default)

Close

Enabled