List of cam objects – ifm electronic RM9000 User Manual

Page 24

Advertising
background image

CANopen encoder

24

Index S-Idx Name

Type,

access

default value

Description

6200

0

Event time

u16, rw

0x64

This object contains the value of the

event timer of the corresponding PDOs�

The value can be set between 1 and

65538 ms�

6300

Cam state

register

The object describes the cam state

register� The object contains the current

position of the cam from 1 to 8�

0h

Number of sub

indices

u8, ro

1h

1h

Cam state

channel 1

u8, romap 4h

6301

Cam enable

register

The object describes the cam state�

0h

Number of sub

indices

u8, ro

1h

1h

Cam enable

channel 1

u8, rw

6302

Cam polarity

register

The object describes the cam behaviour�

0h

Number of sub

indices

u8, ro

1h

1h

Cam polarity

channel 1

u8, rw

0h

List of cam objects

6310h

Cam 1 low limit

0h

VAR

Highest sub-index supported

u32

ro

0x1

1h

VAR

Cam 1 low limit channel 1

u32

rw

0x0

6311h

Cam 2 low limit

0h

VAR

Highest sub-index supported

u32

ro

0x1

1h

VAR

Cam 2 low limit channel 1

u32

rw

0x0

6312h

Cam 3 low limit

0h

VAR

Highest sub-index supported

u8

ro

0x1

1h

VAR

Cam 3 low limit channel 1

u32

rw

0x0

6313h

Cam 4 low limit

0h

VAR

Highest sub-index supported

u8

ro

0x1

1h

VAR

Cam 4 low limit channel 1

u32

rw

0x0

6314h

Cam 5 low limit

0h

VAR

Highest sub-index supported

u8

ro

0x1

1h

VAR

Cam 5 low limit channel 1

u32

rw

0x0

Advertising