Ivoclar Vivadent IvoBase System User Manual

Ivobase, System short instructions

Advertising
background image

IvoBase

®

System

Short Instructions

1

Investing the model

Placing the injection

channels

2

Placing the aeration

channels

Investment in silicone

3

Casting the counter model

Boil out the model

Preparing for injection

– Isolate the inner surfaces with

a thin layer of petroleum jelly

– Place

access former "half"

and

flask lid

in the flask half

– Position the

filter wax

component

– Soak model in water, isolate,

and invest in dental stone
(Class III)

– Access former "half" must be

invested

flush

in the stone

– Allow the stone to set

thoroughly

– Remove access former "half"

and place

access former

"full"

– Position the

injection wax

component

on the

contouring, stone surface and
access former and press on

Maxillary complete dentures
– Press one injection channel

against the center of the
palatal roof

– Place one channel each

vestibular to the two maxillary
tubers and press on

Mandibular complete dentures
– Place injection channels to the

lingual area of the retromolar
triangle

– Separate the center channel

– Press the

aeration wax

component

anterior to the

contouring and to the center
of the filter wax component

Partial dentures
– Place an injection channel at

the dorsal end of each
denture saddle

– Place an aeration channel

anterior to the denture saddle

– Coat the surfaces of the

contoured dentures with

A-silicone

– Do not cover access formers,

occlusal surfaces and incisal

edges

– Provide the silicone with

retentive patterns

– Isolate stone-to-stone contact

surfaces with Separating Fluid

– Position the upper flask half

and lock using the locking
clasps

– Mix conventional dental stone

(Class III) and have it flow into
the flask without any bubbles

Skim off

excess stone

– Allow the stone to set

thoroughly

– Heat in a water bath at 90 °C

for 5-8 min

– Open the flask, remove access

former "full" and roughly
remove wax using a wax knife

– Boil out the inner surfaces

with

clean, boiling water

– Use pure water without any

additives

– Roughen basal and cervical

surfaces of the resin teeth

– Allow flask halves to cool to

below 30 °C

and check

temperature with an IR
thermometer

– Isolate stone surface with

Separating Fluid

– Apply a second coat after

5 minutes

– Insert the

aeration filter

flush into the corresponding
recess in the flask

– Push the IvoBase

funnel

into

the

centering insert

until it

stops and position it

– Assemble the two flask halves

and lock