Ivobase, System short instructions – Ivoclar Vivadent IvoBase System User Manual

Page 2

Advertising
background image

IvoBase

®

System

Short Instructions

4

Mixing the material

5

Loading the injector

Injection and

polymerization

Divesting

– Remove the monomer

container from the capsule

– Remove the capsule seal

– Twist off the sealing cap of

the monomer container

– Pour the monomer into the

open capsule

– Use the spatula to mix the

monomer and polymer in the
capsule to a

homogeneous

mixture

for approx. 20–30 s

– Place capsule on an even

surface

– Place flask with the centering

insert on the capsule

– Insert the flask into the

polymerization chamber

until

it stops

– Close the door of the Injector

– Select the program
– Activate "RMR" key, if desired
– Start
– Start of the program with the

expansion phase

– Remove the flask at the end

of the program

Cool

in cold water for

15 min.

– Remove the locking clasps
– Secure the flask in the dental

press with the

divesting aid

– Lift the upper flask half by

levering it on both sides in the
gap between the flask halves

– Turn over the flask
– Repeat the procedure

– Remove the stone core and

separate capsule

– Divest the dentures from the

stone core using

stone tongs

– Finish and polish dentures as

usual

Please refer to the Instructions for Use for more detailed information

Ivoclar Vivadent AG
9494 Schaan/Liechtenstein

639389/e/2012-12-06/Rev. 0

Program
No.

Material

Duration

Duration
with
RMR*

1

IvoBase Hybrid

35 min

45 min

2

IvoBase High Impact

50 min

60 min

3

SR Ivocap High Impact

55 min

65 min

4

SR Ivocap Clear

55 min

65 min

5

SR Ivocap Elastomer

65 min

6-20

Ivoclar Vivadent – spare

* With the RMR function (residual monomer reduction) the residual monomer content is reduced to below 1%.