Cut-back technique using ips e.max ceram, Design guidelines firing parameters – Ivoclar Vivadent IPS e.max CAD Flow Chart 3-unit bridge User Manual

Page 5

Advertising
background image

Cut-back technique using

IPS e.max Ceram

Bridge after cut-back

Smooth out the attachment point and take

proximal contacts into account. Do not

inhale ceramic dust during finishing – use

exhaust air discharge and wear face mask.

Surface-grind the outer surface,

particularly the functional areas of the

restoration with a fine diamond to smooth

out the surface structure created by the

CAD/CAM process.

Check occlusion, articulation and proximal

contacts.

Do not use diamond discs for finishing

as this may result in predetermined

breaking points.

Fill the inside of the crowns of the previously

cleaned bridge with IPS Object Fix Putty

or Flow and press the selected IPS e.max

CAD Crystallization Pin deeply into the

Object Fix material. Place the restoration on

the IPS e.max CAD Crystallization Tray

immediately.

Finish the interdental areas with fine-grit

diamonds (grit size 40–50 μm), making sure

to observe the connector dimensions

Place the firing tray in the furnace and

conduct the crystallization firing cycle

with the respective parameters.

Design guidelines

Firing parameters

Crystallization/Glaze

Furnace

Stand-by

temperature

B

[°C/°F]

Closing time

S

[min]

Heating rate

t

1

[°C/°F/min]

Firing

temperature

T

1

[°C/°F]

Holding time

H

1

[min]

Heating rate

t

2

[°C/°F/min]

Firing

temperature

T

2

[°C/°F]

Holding time

H

2

[min]

Vacuum 1

1

1

[°C/°F]

1

2

[°C/°F]

Vacuum 2

2

1

[°C/°F]

2

2

[°C/°F]

Long-term

cooling

L

[°C/°F]

Cooling rate

t

l

[°C/°F/min]

Programat
P300
P500
P700

403/757

6:00

90/162

820/1508

0:10

30/54

840/1544

7:00

550/820

1022/1508

820/840

1508/1540 700/1292

0

Note

Cooling after firing

– Remove IPS e.max CAD objects from the furnace after completion of the firing cycle (wait for the acoustic signal of the furnace).

– Allow the objects to cool to room temperature in a place protected from draft.

– Do not touch the hot objects with metal tongs.

– Do not blast or quench the objects.

When using the cut-back technique, IPS e.max Ceram Impulse and Incisal materials are applied in the incisal and/or occlusal area of the milled, reduced IPS e.max CAD pattern.
Make sure to observe the minimum dimensions during the cut-back process and refrain from designing extreme morphologies with undercuts for mamelons.

Anterior region

IPS e.max Ceram veneer

Extension of IPS e.max CAD

Premolar region

Advertising