Zenotec sintering programs

For the sintering process in the Zenotec high-temperature furnaces, the following points should be observed:

If a standard program is used, it is recommended to sinter the restorations on a sintering support base plate under a high-purity

Al

2

O

3

cover. This arrangement helps prevent deformation and discolouration from occurring in the restoration. All standard

sintering programs are matched to this configuration.

If a fast sintering program is used, only the sintering support base plate - without the cover - must be used. Fast sintering is only

suitable for single-tooth restorations.

Check sintering auxiliaries regularly to make sure that they are clean and work properly.

J Zenotec Fire P1
Standard program 1450°C/2h (2642°F/2h):

Temperature 1
[°C] / [°F]

Temperature 2
[°C] / [°F]

Heating rate:
[°C/h] / [°F/h]

Holding time [h]

Heating phase

20/68

900/1652

600/1112

-

Holding phase

900/1652

900/1652

-

0.5

Heating phase

900/1652

1450/2642

200/392

-

Holding phase

1450/2642

1450/2642

-

2

Cooling phase

1450/2642

900/1652

600/1112

-

Cooling phase

900/1652

300/572

500/932

-

- switch off -

Zenotec Fire P1 fast sintering program:

Only suitable for single-tooth restorations!

Temperature 1
[°C] / [°F]

Temperature 2
[°C] / [°F]

Heating rate:
[°C/h] / [°F/h]

Holding time [h]

Heating phase

20/68

1520/2768

1500/2732

-

Holding phase

1520/2768

1520/2768

-

0.5

Cooling phase

1520/2768

300/572

800/1472

-

- switch off -