The shade range of Heliomolar HB includes two transparent
enamel shades which may be used as top layer to further
enhance the esthetic appearance of the final restoration.

* If the exposure time is 40 s, increments of 2.5 mm (A2, A3, B2, C2, GE) and 3.0 mm
(A1, B1, D2, WE, TW, TG,) may be applied.

8. Finishing / Checking the occlusion / Polishing
Remove excess material with suitable finishers (e.g.
Astropol

®

F) or fine diamonds after polymerization. Remove

proximal excess with diamond or tungsten carbide finishers
or finishing strips. Check occlusion and articulation and
make appropriate grinding adjustments to prevent
premature contacts or undesired occlusal deflections on the
surface of the restoration. Polish the restoration to a high
gloss by means of silicone polishers (e.g. Astropol P/
Astropol HP, Astrobrush

®

), polishing discs and polishing

strips.

Additional information
1. If necessary, additional Heliomolar HB can be directly

applied to polymerized material. If the Heliomolar HB
restoration has already been polished, it must first be
roughened and wetted with Heliobond before fresh
Heliomolar HB is applied.

2. Heliomolar HB should be applied at room temperature.

Cool material may be difficult to dispense.

Warning
– Avoid contact of unpolymerized Heliomolar HB with the

skin / mucous membrane or eyes. Unpolymerized
Heliomolar HB may cause a slight irritating effect and
may lead to a sensitization against methacrylates.

– Commercial medical gloves do not provide protection

against the sensitizing effect of methacrylates.

Storage
– Do not use Heliomolar HB after the indicated date of

expiration.

– Storage temperature: 2–28 °C (36–82 °F)
– Close syringes and Cavifils immediately after use.

Exposure to light causes premature polymerization.

– Shelf life: see note on label and packaging

Keep out of the reach of children.
For use in dentistry only.

Date information prepared:
02/2005

Manufacturer:
Ivoclar Vivadent AG
9494 Schaan / Liechtenstein

This material has been developed solely for use in dentistry. Processing should be
carried out strictly according to the Instructions for Use. Liability cannot be accepted
for damages resulting from failure to observe the Instructions or the stipulated area
of application. The user is responsible for testing the material for its suitability and
use for any purpose not explicitly stated in the Instructions. Descriptions and data
constitute no warranty of attributes and are not binding.