Ivoclar Vivadent Skyce User Manual

Page 2

Advertising
background image

5. Carefully dry the tooth surface.

6. Apply a thin coat of Heliobond or Tetric Evo-

Flow onto the etched region.

7. Apply Heliobond or Tetric EvoFlow to the clean

reverse side of Skyce and place the stone on
the tooth surface. Some Heliobond or Tetric
EvoFlow must come out along the sides of the
stone to provide a setting for the stone.

Recommendation
In order to optimize the bond, fully coat the stone
with a thin layer of Heliobond. This does not
impair the lustre of the stone.
Note: Tetric EvoFlow is unsuitable for this pur-
pose.

Important
Setting the tooth jewellery with Heliobond
or Tetric EvoFlow.

8. The jewel must be light cured for at least 40 s

both from the labial and palatal aspects (eg
with bluephase

®

).

9. If, in rare cases, excess has to be removed, only

use silicone polishers. Rotary instruments must
not touch the stone to prevent scratching.

Notes
1. It is easier to apply Skyce if it is held with a

probe to which soft wax or a bit of adhesive
material from the tip of a OptraStick has been
applied.

2. Do not touch the stone with your fingers or

allow it to become contaminated with saliva. If
Skyce is contaminated, carefully clean the stone
with acrylic pellets in an alcohol bath.

3. For information about the side effects and

interactions of the cementation materials and
the phosphoric acid gel as well as any
warnings, see the corresponding Instructions
for use

4. Skyce can be removed whenever desired.

Keep out of the reach of children.
For use in dentistry only.

Heliobond completely covers Skyce

Skyce with excess Heliobond

Skyce with excess Tetric EvoFlow