INSTALLATION

2

The internal LEDs of the C-BOX 3X0 (see Figure 15) indicate the following:

POWER ON

(

PWR

)

(red) indicates the C-BOX 3X0 is connected to the power
supply and the power switch is ON.

WARNING

(

WL

)

(red) indicates a warning or error condition. It is ON when
a connection procedure is in progress (the system is
busy), during a GET/TEST/SEND procedure or during the
Configuration Mode. It blinks when an error condition
occurs. Normally this LED should be OFF.

BUS ACTIVITY

(

BA

)

(green) indicates the Profibus Network activity. When
communication takes place, this LED will blink slightly.

TRANSMISSION

(

TX

)

(green) indicates there is communication between the
Application and the DeviceNet module. Upon
communication, this LED will blink slightly.

MODULE STATUS

(

MS

)

(green) OFF = Bus off-line or power not supplied.

ON = Bus in Data Exchange Mode.
Flashing = Bus in Clear Mode.

(red)

OFF = No error or power not supplied.
ON = Error in initialisation of Profibus ASIC.
Flashing = Error in configuration data and / or in
user parameter data.

POWER POLARITY ERROR

(red) indicates a wrong polarity. While activated, all other
LEDs will be off until the power feed is connected with
correct polarity.