2.9 SPECIAL NOTES FOR MATRIX READER SETUP

CAUTION

When connected to a C-BOX 3x0 through the 25-pin connector, the
9-pin Auxiliary port connector on the Matrix reader cannot be used
for communication (i.e. configuration through VisiSet™). The Matrix
reader can only be configured through the 9-pin connector inside
the C-BOX 3x0 and the C-BOX 3x0 must first be configured. see
the following paragraphs for details.


2.9.1

Preparing C-Box 3x0 for Matrix Reader Communication


This paragraph describes how to configure a C-BOX 3x0 so that a Matrix reader can
communicate through the C-Box3x0 and also be configured through its Auxiliary
RS232 interface.

1. Open the C-BOX 3x0;

2. Move

the

Configuration Switch from the Normal Operation to the CFG position;

3. Connect the 9-pin internal connector of the C-BOX 3x0 to the PC (using a

crossover cable) and run the Winhost™ configuration tool;

4. Select

the

Connect option to open communications with the C-BOX 3X0 and

wait until the correct communication speed has been determined;

5. From the SCANNER INTERFACE menu, set Auto Connect: Disabled and verify

Data Source: Main Interface and save the configuration to the C-Box 3x0 (refer
to Figure 17);

Figure 17 – WinHost Configuration Menu for C-Box 3x0

6. Return

the

Configuration Switch to the Normal Operation position.