Operation disturbances, Accessories – Kemppi DC 3500W User Manual

Page 19

Advertising
background image

9901 / 1916110E / 19

English

6.2 Cables

Check the condition of the welding and connection

cables daily. Do not use damaged cables!

Check also that the mains connection cables that you

use are in good condition and that they comply with all

the regulations!

Mains connection cables may be repaired and installed

only by an authorized electric shop or electrician.

6.3 The power source

NOTE! Disconnect the plug of the machine from the

mains socket and wait for ca. 2 minutes (capacitor

charge) before removing the casing plate.
Check at least very six months:

– The electric connections of the machine– clean any

oxidized parts and tighten any loose ones.

NOTE! You must know the correct tension torques

before you start to repair the connections.

– Clean the inner parts of the machine from dust and

dirt e.g. with a soft brush and a vacuum-cleaner.

Do not use pressurized air, because there is the

danger that the dirt is packed even more tightly in

the gaps of the cooling profiles. Do not use a pres-

sure washing device.

Only an authorized electric shop or electrician may re-

pair the machine.

6.4 Regular maintenance

KEMPPI Service Repair Shops handle regular mainte-

nance by agreement.
Regular maintenance includes e.g. the following:

– Cleaning of the machine.

– Checking and maintenance of the welding tools.

– Checking the clamps, switches and potentiome-

ters.

– Checking the electric connections.

– Checking the mains cable and plug.

– Replacement of any parts that are damaged or in

poor condition.

– Maintenance testing. The operation and perform-

ance values of the machine are checked and,

where necessary, adjusted by means of test equip-

ment.

7. OPERATION DISTURBANCES

In the case of operation disturbances, contact an au-

thorized KEMPPI Service Repair Shop.

Check the maintenance parts before sending the ma-

chine to the service shop.

8. ACCESSORIES

8.1 Remote control units

C 100C

Control of MMA / TIG welding current, memory scale

1 - 10.

C 100D

Control and fine-tuning of MMA / TIG welding current,

memory scale 1 - 10.

C 100AC

Control of MMA / TIG welding current, memory scale

1 - 10 and MMA / TIG selection.

C 100F

Foot pedal control unit for TIG welding

– start function

– adjustment of the welding current with pedal move-

ments

– limitation of the welding-current range with min and

max potentiometers

Connecting the foot pedal unit

:

The foot pedal unit has two connections, which are

connected to the remote control and start connections

in the rear of the power source. When using the foot

pedal unit, the maximum current output of the machine

is ca. 30 % below its maximum output unless the ma-

chine is calibrated for the foot pedal unit.
Calibration of the machine for the foot pedal unit:

1. Turn the machine off.

2. Press the REMOTE key and at the same time turn

the machine on; the display will show the text rEn 01.

3. Turn the current adjustment knob so that the dis-

play will show rEn 02. (01=C 100C, 02=C 100F)

4. Press the REMOTE key so that the setting is saved

in the memory.

C 100C

C 100D

C 100AC

Advertising