Extra functions – Kemppi DC 3500W User Manual

Page 20

Advertising
background image

20 / 1916110E / 9901

English

8.2 Wheel barrows and transport chassises

T 120 (transport unit)

Mastertig AC/DC 1600, 2500, 2500W, 3500W

post gas button. All jumper settings are then saved

in the memory.

Jumper functions are:

(Factory settings are underlined)

J01: [On] = slope of up slope is constant, up slope time

depends on set value of current.

Off = up slope time is independed of set value

of current.

J02: [On] = slope of down slope is constant, down

slope time depends on set value of current.

Off = down slope time is independed of set val-

ue of current.

J03: On = TIG antifreeze is on.

[Off] = TIG antifreeze is not in use.

J04: [On] = manual AC balance control.

Off = balance function in use.

J05: [On] = tag welding automatics on.

Off = tag welding automatics is not in use.

J06: [On] = down slope falls to minimum end level cur-

rent (3 A DC, 10 A AC)

Off = down slope falls down to end level which

is 20 % of the welding current

J07: [On] = open-circuit voltage is 39 V

Off = open-circuit voltage is 70 V

J08: [On] = when stopping welding with 4T function

the down slope starts by pressing torch connec-

tor. Slope continues as long as you press the con-

nector. Current stays at end level in case you press

longer than down slope´s normal time (look J06).

Off = 4T function is as it has been described on

the operation instructions.

J09 ... J15 Not in use.

J16: Length of positive start cycle of AC-TIG 0.0 ... 2.0,

factory setting is 1.

J17: Adjustment of MMA ignition pulse 0.0 ... 2.0, fac-

tory setting is 1.

Do not lift the

welding machine

and the transport

unit with a gas

bottle.

lifting ear

T 22 (transport unit)

Mastertig AC/DC 2500,

2500W, 3500W

9. EXTRA FUNCTIONS

There is extra functions and selections in the machine,

which are not seen in the panel. The welder needs the-

se functions not in normal welding, but they may be a

solution in some special cases. These function are cal-

led jumper-functions, because they are behind jumper

numbers. Function can be On/Off -type or adjustable

parameter.

Jumper functions are used as follows:

1. Turn off the machine.

2. Press the post gas button and in the same time

turn the machine on. You can see text (SE.1 000)

on the panel.

3. Press once the pre gas button. Now text (J01 OFF)

or (J01 On) is on te panel.

4. Choose jumper number, which you want by pres-

sing REMOTE button.

5. Change setting of the jumper with current knob I2.

6. When you have done all changes press once the

lifting ears

on the both sides (total 4 pcs)

Advertising