1

System Introduction

2-3

Configuring the System

4-9

Setting a House ID

4

Creating Groups

5-6

Setting up Remote Controls

7-9

Custom Settings

10-11

Expanding the System and Interfacing

12-16

with Other Programs

Operating the System

17-20

Designing a System

21

Product Overview

22-25

Specifications

26-28

Frequently Asked Questions

29-30

SAFETY CONSIDERATIONS

TABLE OF CONTENTS

Safety Considerations

Lamp Replacement

It is a safety requirement that lighting loads be electrically isolated for relamping. To
do this, use the air-gap switch to the right of the adorne device as shown and move the
switch upwards. When the LED goes out, the load is safely isolated for relamping. To
restore normal operation, move the switch back to the down position.

Dimmer Derating

For multi-gang installations, use pliers to break off the specified heat sink fins.

De-rate the maximum load according to the following table.

Overload Protection

adorne Wireless Lighting dimmers and switches feature overload and short-circuit
protection. In the event of an overload condition, the device will stop working, and the
status LED will be rapidly flashing red at 2 Hz. Set the dimmer to off, disconnect loads
in excess of the dimmer’s rating, and try again.

Table of Contents

Rated Load

2-Gang Installation

3-Gang Installation

Incandescent/Halogen

700W

600W/600W

600W/500W/600W

MLV

700VA

600VA/600VA

600VA/500VA/600VA

EFL

5.5A

5.5A/5.5A

5A/5A/5A

ELV

700W

600W/600W

600W/500W/600W

Airgap Switch

Flashing Red