Spectra, Lencore – Lencore Spectra Classic: Installation and Operations Manual User Manual

Page 3

Advertising
background image

spectra

Lencore

All Wire must be UL Usted, Plenum Rated, 18 gauge, stranded, non-shielded

NOTE

If private offices are included, units should be set

lower in these offices. Suggest 3 clicks on

center switch and 1/2 turn on gain control.

On each main (master) unit, turn each center volume control on the main

(masters) seven clicks & the blue gain control 3/4 clockwise. This is especially

helpful when using a CVC unit. In that case, if the volume is slightly up or down,

all of the units can be adjusted by the CVC. This saves a great deal of time. This

may vary depending on the quantity of units and the height of the plenum area.

Masking units come from the factory pre-set for mineral fiber ceiling tile. If glass

fiber ceiling tile is used, the contour switch must be turned 3/4 to the left towards

the pink spectrum

Leave enough cable at each ceiling opening so that you have an extra 3-5 ft. This

cable will be made into a loop once the unit has been hung and put in the ceiling

using a 7” wire tie. The cabling connecting the units should not be too tight. Once

installed, cable cannot touch the ceiling (use the wire ties to accomplish this).