cvc questions

LOSS OF POWER IN UNITS WHEN HOME RUN IS CONNECTED TO CVC?

Make sure that you have connected the brown & red wires in addition to the blue &
black wires . Make sure you have NOT connected the white wire between the CVC and
a Main. (White wire is only used when connecting a Main/CVC to a Secondary). Recheck
wiring of CVC. If everything checks out- you may have a bad CVC.

HOW DO YOU CONNECT A CVC?

Connect the CVC to a Main near the middle of a run the way you would connect any
other Main. Refer to the appropriate wiring diagram for the correct CVC wiring.

CAN YOU HOOK-UP SECONDARYS TO A CVC?

Yes, a CVC is treated like a regular Main in area it is placed. When doing this we
recommend hooking up only one Secondary to a CVC. Refer to the appropriate wiring
diagram for the correct eve wiring.

IF A PROGRAMMABLE TIMER HAS BEEN INCLUDED IN YOUR PROJECT , PLEASE
CONSULT THE TIMER MANUAL. (CVC’S ARE NOT REQUIRED WHEN USING A
PROGRAMMABLE TIMER)

.