It takes approximately 30 seconds for meter to respond to sound. 0 to
50 dB...you want the reading to be to the left of the 0. -10 would be 40
dB. You need a reading between -2.5 and 1.5 on the meter. This would
be 47.5 to 48.5dB. It would naturally be high with the ceiling open.

instructions for using the simpson model 884-2

(or equivalent sound meter)

1

2

3

4

Turn large round dial to 50.

Make sure fast/slow setting is on slow.

Hold meter approximately 4’ above floor.

Note meter reading after one minute.

Approximately 2 weeks after install, or when ceiling tiles

and furniture are all in place, reset units to 47.5 to 48.5 dB

four feet above floor.