1)

Introduction

Watson provides two important functions to support new technology (non-incandescent)
lighting fixtures.

1) Power Switching – using a set DMX address, or simply detecting DMX signal,

Watson will turn off the power to fixtures when they are not in use.

2) Isolated DMX data – Watson provides optically isolated and buffered signal for a

series of DMX fixtures.

Please take a few minutes to review the specifications features of the new Watson
product.

2) Features and Specifications

Power Connection

Power input Connector

Neutrik PowerCon

Mating connector

Neutrik NAC3FCA

Operating voltage

110 – 240 VAC

Maximum load current

15 amps

Ambient Temperature

Watson Power Management systems are designed to operate in an environment where
the ambient temperature is less than 40 degrees Celsius, or 104 degrees Fahrenheit.

Load Connector

Depending on the model purchased, your Watson Power System will use either
Powercon or standard NEMA 5-15 load connectors. Please note that Powercon
connectors are NOT designed to be connected under load. Please turn off the circuit
breaker on Watson before connecting power or load. PowerCON load connector is
Neutrik NAC3MPB-1, and the mating cable mount connector is NAC3FCB.