ISOseries Installation guide


2.0 Installation


2.1 Isopower Rack mount

The ISOPOWER ISPR is designed for 19” rack installation. All connections are made at the
back of the chassis. The mains power supply is connected to the IEC input connector. Two
24VDC outputs are provided on 4mm² screw terminals. Output 1 and output 2 are internally
hardwired together which allows multiple ISOPOWERs to be connected together for larger
installations where load sharing and system redundancy is required.


2.2 Isopower Wall mount

The ISOPOWER ISPW can be installed onto any flat horizontal or vertical surface. Four
mounting holes are located in each corner of the chassis. A protective cover at one end
details the connector configuration for the screw terminals found underneath the cover.

ISPW connections with cover removed

ISPR connections at rear of chassis