Installation, Warning, Installing and framing the fireplace – Montigo B34DV User Manual

Page 4: Page 4 b-series dv-2 gas fireplace, Framing, Clearances, Top view front view side view

Advertising
background image

Page 4

B-Series DV-2 Gas Fireplace

Part No. XG0160 -141231

Installation

Installing and Framing the Fireplace

The

B-Series-DV-2

fireplaces may be installed in any location that main-

tains proper clearances to air conditioning ducts, electrical wiring and

plumbing. Safety, as well as efficiency of operation, must be considered

when selecting the fireplace location. Try to select a location that does

not interfere with room traffic, has adequate ventilation, and offers an

accessible pathway for Direct Vent installation. Refer to page 5 - Vent

Installation for more information.
The fireplace dimensions are shown below:

Figure 4. Minimum Corner framing dimensions, using a 45° elbow.

Figure 3. Framing dimensions.

(

When sheetrock is

not used behind the

fireplace, framing

depth "O" may be

reduced by 5/8")

Framing

Top View

Front View

Side View

Clearances

These clearances apply to all dimensions except the framed opening,

where the clearance to combustibles is 0". The B-Series DV-2 clearances

to combustible materials are:

B34-DV-2-TV B34-DV-2 RV B38-DV-2-TV B38-DV-2-RV

Top - Rear Vent *

N/A

8"

N/A

9 1/4"

Top - Top Vent

15"

N/A

15"

N/A

Back

0"

1"

1"

1"

Sides

1"

1"

0"

0"

Floor

0"

0"

0"

0"

Mantle**

8"

8"

6"

6"

Flue

1 1/2"

1 1/2"

1"

1"

* Clearance from the top of the fireplace to a combustible ceiling

within the fireplace enclosure.

** Refer to page 12,

(Mantels and Surrounds).

Unprotected combustible walls which are perpendicular to the fireplace

opening, must not project beyond the area shown in Figure 23.
For protection against freezing temperatures, it is recommended that

outer walls of the chase be insulated with a vapor barrier. This will reduce

the possibility of a cold-air convection current on the fireplace.

Figure 1. Fireplace dimensions.

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

A

B

C

D

E

F

G

H

I

J

K

L

B34-DV-2 33

3

/

4

31

1

/

2

31

1

/

4

1

1

/

4

18

1 13

3

/

4

21

3

/

4

8

4

7 25

1

/

4

B38-DV-2 37

3

/

4

34

1

/

2

34

3

/

4

1

1

/

4

21

1 15

7

/

8

24

1

/

8

9

4

7 28

3

/

8

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

L

M

N

O

P

Q

S

T

B34-DV-2

25

1

/

4

36

3

/

4

33

15

1

/

2

50

35

3

/

8

30

3

/

8

39

7

/

8

B38-DV-2

28

3

/

8

39

3

/

4

37

17

5

/

8

56

39

5

/

8

33

3

/

8

42

7

/

8

When installing a shelf over the top of the fireplace, the following guidelines

must be adhered to: For Rear Vent applications the minimum clearance

from the top of the fireplace to a shelf is 8". For Top Vent applications, the

minimum clearance is 15". (

Minimum clearance to combustible construction

around the vent pipe is 1" on all sides, except on horizontal venting where the

top of the pipe must have a clearance of at least 2".

)

Figure 2. Framing for shelves over the fireplace.

Top Vent

Rear Vent

(On Applicable Models)

WARNING!

When this appliance is installed directly on any combustible mate-

rial other than wood flooring, it must be installed on a metal or

wood panel extending the full width and depth of the appliance.

M

8”

S

Header

Shelf

L

T

15”

Header

MEL Short

Shelf

M

2” Min