4.3.2 Connecting several frames together

Several frames can be connected to each other through the RS-422 ports on the rear of
each frame.
One GYDA-SC controller can control maximum 8 frames.
You start with the frame containing the GYDA-SC Rack System Controller, and use 1 RS-
422 port to loop through to the next.
The last frame connected must be terminated with 110

in order to ensure proper

operation. The other port of the rack containing the GYDA-SC controller must be left open,
and cannot be connected to other frames.
Figure 5 shows an example of how to connect 8 frames together as seen from the rear end.
By using the RS-422 interface at the GYDA-SC controller card, we control 8 frames via one
RS-422 bus.

Figure 9: Control of 8 frames with GYDA-SC.

The 110

termination plug used is a standard RJ45 plug with the following internal wiring:

Figure 10: RS-422 termination.

In the figure above, Pin 1 is connected to Pin 2 with a 110

resistor, and Pin 3 is connected

to Pin 6 with a 110

resistor.

1 2 3 6