3 configuration, 1 address setting on each frame, 3configuration – Nevion FR202 User Manual

Page 9

Advertising
background image

FR-2RU-20-2

Rev. A


nevion.com | 9

3

Configuration

3.1 Address setting on each frame

Each frame can be assigned an address through the rotary switches on the rear. Maximum
8 frame addresses (0-7) are available

, this means that pos. “8” and “9” on the rotary switch

are not valid
This address setting only applies when the frame is used in combination with a GYDA-SC
Rack System Controller.
If you have more than 8 frames together, you need several GYDA-SC Rack System
Controller cards.

In order to ensure proper operation of the system, it is important that no frames
controlled by the same GYDA-SC Rack System Controller card have the same
address set.

Reset the frame after reconfiguring the frame system, by turning the power off
and on again.

Figure 4: Rotary switch

More detailed information on the RS-422 configuration can be found in a separate
document and at our web site:

http://www.nevion.com/






















Valid positions: 0-7