Electrical connections, Mechanical installation – Datalogic Scanning DS2200 User Manual

Page 3

Advertising
background image

DS2200 QUICK GUIDE

3

Electrical Connections:


DS2200 is equipped with a cable terminated by a 25-pin female D-sub connector for connection with the power
supply and input/output signals.

CAUTION

Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.



The details of the connector pins are indicated in the following table:

25-pin D-sub female connector pinout

Pin Name

Function

9, 13

VS

Power supply input voltage +

25

GND

Power supply input voltage -

1 CHASSIS

Chassis

ground

19

EXT TRIG- External Trigger -

10, 12, 22

I/O REF

I/O Reference

8 OUT1+

Output

1+

11 OUT2+

Output

2+

2

TXAUX

TX RS232 Aux. Interface

3

RXAUX

RX RS232 Aux. Interface

4

RTX485-

RTX- RS485 Main Interface

5

RTX485+

RTX+ RS485 Main Interface

7 SGND

Signal

Ground

16

NGND

Internal Use – for Service only

17

FPE

Internal Use – for Service only

6, 14, 15, 18, 20, 21, 23, 24 NC

No Connect

25-pin female connector


Mechanical Installation:

mm

inch

8.

5

0.

33

50

1.

97

40

1.57

8.2*

0.32

28

1.10

M 2.5 n° 3

33.5
1.32

40

.5

1.

59

3.

25

0.

18

2.7 n° 4

48.5

40.5

2 x

45

°

4

30

2

10

16.

8

6.

7

6.

7

2

25

3.2

14

3.

2

15

26.5

90°

2.

5 x 45

° n

°2

mm


*
The quote refers to the scan line

Advertising