Input/output connections, Connectivity – Datalogic Scanning DS2200 User Manual

Page 4

Advertising
background image

DS2200 QUICK GUIDE

4

Input/Output Connections:

Input Output

Signal

EXT TRIG-

19

VS = 5 Vdc

9/13

22

I/O REF

Ground

EXTERNAL TRIGGER

DS2200

V

+ 5V

47K

External Trigger Input Command

DS2200

USER INTERFACE

Vext

50 Vdc max, 50 mA max.

OUT 1+ / OUT 2+

8/11

10/12/22

I/O REF

Output Connections



V

CE

max = 50 Vdc

I max = 50 mA continuous


Connectivity:

RS232 Point-to-point layout

1

2

Host

DS2200

c

RS232 Auxiliary Serial Interface

d

External Trigger (for On-Line mode)



RS485 Master/Slave layout

Host

DS2200

Slave

DS2200

Slave

DS2200

Master

1

2

3

1

1

c

RS232 Auxiliary Serial Interface

d

RS485 HD Main Serial Interface

e

External Trigger