3 front panel, Status monitoring, 3 front panel – status monitoring – Nevion 3GHD-OE-L-2-SFP User Manual
Page 25
3GHD-OE-L-2-SFP
Rev. C
nevion.com | 25
LOS2
Loss of signal on input 2.
Only for dual converter
Pin 3 Open Collector
Ground
0V / gnd pin.
Pin 8 0V.
Figure 25 GPI connector
5.3 Front panel
– Status monitoring
The status of the module can be easily monitored visually by the LED’s at the front of the
module. The LED’s are visible through the front panel as shown in the figure below.
Figure 26
Front panel LED’s
The 3GHD-OE-L-2-SFP has 3
LED’s each showing a status corresponding to the GPI
pinning. When DIP#3 is on the LED’s are used as an optical power meter.
Table 9
Front panel LED’s
Diode \ State
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty, or
module is
initializing.
N/A
Module is OK
Module power is OK
Module has no
power
LOS/LOCK1 No input signal on
electrical output 1.
Input signal on
electrical output
Input signal on
electrical output 1