3.3 Panel Group Setup

On the back of each control panel there is a DIP-Switch block used for putting a control panel
into panel groups. Panel group is used for mapping a control panel configuration file to a
panel. If several control panels should have the same functionality, just put them into the
same panel group. Every changes made to the control panel configuration file will be applied
to all the control panels in the same panel group. You may also put all control panels into
unique groups and apply the same configuration file the each group.

You may only include same type of control panels in the same panel group!

The drawing below shows a typical system setup:

Figure 11: Panel Group setup

3.4 DIP switches on the panel

The dipswitches on the rear of the panel are used to configure settings that are supposed to
be fixed during operation of the panel.

Look for the OPEN, or ON text on the switch block, to verify correct position of the
dipswitches.

The ON/OFF silkscreen text on the panel is NOT valid for the Piano Type
switches.

The figure below shows both types of dipswitch blocks that may be used on this panel.

Piano Type switch

Straight Type switch

Figure 12: Dipswitch blocks