background image

on again and check the Over-temperature state on the BUC GUI window.

3) When Over-power became red on the BUC GUI window.

-

IF input power is too high

 Check the IF input power level.

-

Or, the BUC is faulty

 Contact NORSAT for further support.

4) When External Mute became red on the BUC GUI window.

-

External Mute pin is not connected to ground.

 Check the External Mute wire connected to ground.

-

Or, the BUC is faulty

 Contact NORSAT for further support

B) RF output power is low even if SSPA is on

1) Gain setting on the BUC GUI window is too low

 Check gain setting on the BUC GUI.

2) Input IF power is too low to drive the BUC properly

 Check the output level of the IF power source.

3) IF cable or connectors has high insertion loss

 Check the IF cable or connectors.

4) RF cable or connector or WR28 waveguide adapter has high insertion loss

 Check the RF cable, connector, or WR28 waveguide adapter.

5) One of internal components are faulty

 Contact NORSAT for further support.






© 2014 Norsat International Inc.