Remko mkt – REMKO MKT 251 User Manual

Page 12

Advertising
background image

n

Check whether the stopper in the condensate

drain is present and correctly installed. There is

a risk of uncontrolled condensate leakage after

commissioning.

1

Fig. 7: Condensate drain

1: Condensate drainage with stopper

n

Never operate the unit without the air inlet filter.

Otherwise, the fins of the heat exchanger can

become dirty and the unit loses performance.

1

Fig. 8: Air inlet filter

1: Recirculated air filter

n

Ensure that persons and sensitive objects,

such as plants, are not placed directly in the air

flow emerging from the unit.

In addition, with direct solar radiation close the

curtains and blinds and keep the windows and

doors closed during operation.

Conduct the warm exhaust air away

NOTICE!

The exhaust air hose should always be laid

rising in the direction of air flow and must not

be extended!

In cooling mode the unit creates warm moist

exhaust air, which must be conducted away from

the room to be cooled. For this reason it is neces-

sary to plug the exhaust air hose into the outlet

opening on the rear of the unit.

n

Ensure that the catches for the exhaust air

hose latch securely into the two openings of

the connection aperture. In order to be sure of

effective operation, do not lay the flexible

exhaust air hose with tight bends and do not

kink it and to prevent damage resulting to avoid

air carrying components!

Fig. 9: Latch the hose into place

n

The exhaust air of the unit contains a certain

amount of moisture. For this reason it is advis-

able to feed the exhaust air to the outdoor area

or to outdoors.

Exhaust air routing variants

You can route the exhaust air out of the building as

follows:

Via a flat nozzle

The flat nozzle supplied can be used in various dif-

ferent ways. It is possible to feed the flat nozzle

through an open window and fasten it by means of

Velcro and a window suction cup (Fig. 10). Like-

wise the flat nozzle can be hung in a tilted window

(Fig. 11).

REMKO MKT