2 technical data, 1 unit data, Technical data 2.1 unit data – REMKO MKT 251 User Manual

Page 7: 2technical data

Advertising
background image

2

Technical data

2.1 Unit data

Series

MKT 251

MKT 251

Operating mode

Local compact air conditioning unit for cooling

Nominal cooling output

1)

kW

2.60

Energy efficiency ratio - cooling

A

Energy efficiency rating EER

1)

2.63

Energy consumption, hourly

kWh/60 min

0.99

Approx. application area (room volume)

80

Adjustment range indoor unit

°C

+16 to +32

Operating range - indoor unit

°C/%r.F.

+16 to +35 / +35 to +85

Refrigerant

R 410A

3)

Refrigerant, basic capacity

kg

0.5

Max. operating pressure / cooling cycle

kPa

1800 / 3600

Air flow volume per stage

m³/h

240 / 270 / 320

Sound pressure level per stage

2)

dB(A)

49 / 52 / 53

Sound power level max.

dB(A)

62

Power supply

V/Ph/Hz

230 / 1~/ 50

Enclosure class

IP

20

Electr. rated power consumption

1)

kW

0.99

Electr. rated current consumption

1)

A

4.78

Elec. starting current max., LRA

A

17

Exhaust air hose, length / diameter

mm

1500 / 125

Dimensions - height

mm

770

Dimensions - width

mm

435

Dimensions - depth

mm

430

Weight

kg

33.0

Standard colour

white

silver

Serial number

1254...

1255...

EDP no.

1612255

1612256

1)

Room air temperature TK 35

℃, FK 24 ℃

2)

Distance 1m free field

3)

Contains greenhouse gas according to Kyoto protocol

7