Fault description

Cause

Remedy

The unit does not cool prop-

erly

LED cooling indicator

The "Cool" LED indicator must illuminate

Close windows, doors,

blinds and curtains

Exhaust air hose

Must be properly attached. It must not be kinked,

sloping downwards or laid in bends that are too

tight.

Air feed and air exhaust

There must be no foreign bodies impairing these

(observe minimum clearance)

Ventilation louvres

Must be free of dirt and foreign objects

Target temperature

adjustment

Must not be set too high (unit operating range

+16 to +35 °C).

The unit does not respond to

the remote control

Remote control

There must be no objects between the remote

control and the unit (range ca. 5 m).

Batteries

Ensure that

the batteries are in good working order, other-

wise replace the batteries

the batteries have been inserted with the correct

polarity (see markings)

Condensate leaks out of unit

Unit standing at an

angle

Position vertically, ensure stable horizontal base

Stopper in condensate

drain hose missing

Seal the hose so that it is watertight again

Exhaust air hose not

correctly seated

Connect correctly