10 shutdown, Shutdown, Remko mkt – REMKO MKT 251 User Manual

Page 20

Advertising
background image

Fig. 17: Cleaning with lukewarm water

10

Shutdown

NOTICE!

Never switch off the equipment by pulling out

the mains plug.

Temporary shutdown

If it is planned to shut down the unit for longer

periods e.g. during the winter, proceed as follows:

1.

Let the unit run in recirculating operation for

ca. 2 hours in order to dry the surfaces of the

evaporator fins. This will transport the

remaining moisture out of the unit and this

will avoid unpleasant odours when the unit is

re-commissioned.

2.

Switch the unit off with the "POWER" key,

pull out the power plug and wind up the

power supply. Ensure that the wiring is not

kinked or too severely bent.

3.

Place a suitable container underneath the

condensate drain of the internal reservoir.

The condensate drain is located on the lower

rear side of the unit.

4.

Pull out the stopper from the condensate

drain and collect the condensate that drains

out.

5.

Then insert the stopper once again. A

missing stopper or an incorrectly inserted

stopper will result in condensate leaking out

after re-commissioning.

6.

Store the unit in an upright position in a cool,

dry and dust-free location protected from

direct sunlight. Cover the unit with a synthetic

cover to protect it against dust if desired.

Permanent shutdown

The entire system should only be dismantled by a

specialist firm familiar with all environmental

aspects involved. REMKO GmbH & Co. KG or your

sales partner will be pleased to provide details of

refrigerant specialists in your area.

REMKO MKT