Drains

All models require drain tubing to be attached to them.

Air cooled models have a single ¾” FPT drain fitting

in the back of the cabinet. Water cooled models have

the same fitting plus an additional ½” FPT drain fitting

in the back of the cabinet. Install new tubing when

replacing a prior ice machine, as the tubing will have

been sized for the old model and might not be correct

for this one.

1. Connect water supply to water inlet fittings.

Note: This NSF listed model has a 1" anti-back

flow air gap between the end of the water inlet tube

and the highest possible reservoir water level, no

additional back flow device is required for the potable

water inlet.

2. Connect drain tubing to drain fittings.

3. Route the drain tubing to building drain. Follow

local codes for air gap.

Use rigid drain tubes and then route them separately

– do not Tee into the bin’s drain or, if water cooled,

Tee the condenser drain into the reservoir or bin drain.

Vent the reservoir drain. A vertical vent at the back of

the drain, extended about 8 – 10” will allow the gravity

drain to empty and also keep any surges during

draining from discharging water.

Horizontal runs of drain tubing need a ¼” per fall per

foot of run for proper draining. Follow all applicable

codes.

Water Supply and Drain Connections

Water Inlet

Connection

Potable

Water

Supply

Floor Drain

Water Cooled

Condenser

Inlet

Water Cooled

Condenser

Drain

Optional Water

Filters

Reservoir

Drain