Adjustments

Bridge Thickness - For Service Tech Only

1. Push and hold Off till the machine stops.

2. Remove evaporator cover.

3. Remove curtain.

4. Use a box wrench and rotate the bridge thickness

adjustment screw in 1/8 turn increments CW to

increase bridge thickness.

5. Rotate CCW to decrease bridge thickness.

Caution: Do not make the bridge too thin or the

machine will not harvest properly. Bridge thickness

adjustments are not covered by warranty.

6. Return curtain to its normal position.

7. Push and release the On button. Check next

harvest of ice. Repeat steps 1-6 if needed.

Note: Water cooled models, the refrigeration system

discharge pressure is factory set at 245 PSIG,

which should yield a freeze cycle discharge water

temperature of about 105-110 degrees F. Adjust if

necessary.

Ice Bridge Thickness Check

Ice Thickness Sensor

Too Big

Just Right for

Small Cube

Just Right for

Medium Cube

Too

Thin

1/8 - 3/16” bridge