Initial Start Up

1. Remove front panel. Check machine for any

packing or wires rubbing moving parts.

2. Switch on the electrical power to the machine.

Observe that some of the control’s indicator lights

glow and its display shows O.

3. Open the water supply valve.

4. Push and release the

lower light and switch

panel’s ON button. The indicator light will begin

to blink F.

The purge valve will open and the water pump will

start. The inlet water valve will open to add water to

the reservoir. After a few seconds the purge valve will

close and the water pump will stop. Water will flow

into the machine until the reservoir is full. The hot gas

valves and harvest assist devices will activate then

the compressor and water pump will start. If its an air

cooled model the fan motors will begin to turn. The

display will show a continuous F. Five seconds later

the hot gas valves will close and the harvest assist

device will return to its standby position. Warm air will

be discharged from air cooled models.

5. Observe the Ready for Harvest indicator light. It

may blink early in the cycle, that is normal. The

control will ignore that signal for the first 6 minutes

of freeze.

6. During the Freeze cycle open and close the

curtains. The SW1 and SW2 lights on the control

board will blink ON when each curtain is opened

and OFF when closed.

Note: Moving a curtain during the Freeze cycle has no

affect on the control, but will cause water to flow into

the cube chute.

7. When the ice has frozen enough, the Ready for

Harvest indicator light will be on steady. After it’s

been on steady for a few seconds Harvest will

begin.

8. The display shows an H.

The hot gas valves open, the air cooled fan motors

shut off and the harvest assist mechanisms are

activated. The purge valve opens to drain some water,

when it does the inlet water valve opens to refill the

reservoir. After a few seconds the purge valve closes

but the inlet water valve continues to fill the reservoir.

Harvest continues until the ice is released as a unit

and forces the curtain to open. When both curtains re-

close the controller returns the unit to a freeze cycle.

9. Check the ice harvested for proper bridge

thickness. The ice bridge is factory set at 3/16

inch. If needed, adjust bridge thickness. Do NOT

make it too thin.

10. Determine the water purge setting from the table

on page 15. If desired, change the setting to

accommodate the local water conditions.

11. Return the front panel to its normal position and

secure it to the machine.

12. Instruct the user in the operation of the machine

and its maintenance requirements.

13. Fill out and mail warranty registration form or

register on line at www.scotsman-ice.com.

Typical Ice Making Cycle Times (minutes).
Listed times are for clean machines in proper

installations. Cycle length at start up will be longer

until the system stabilizes.

Model

70

o

F. air / 50

o

F.

water

90

o

F. air / 70

o

F.

water

C1448A

12-14

14-16

C1448W

13-15

14-16

C1848A

9-11

12-14

C1848W

9-11

10-12