11. Wash the sensor and the adjustment screw with

ice machine scale remover solution, rinse with

clean water. Also wash the water distributor and

curtain with the ice machine cleaner solution.

12. Locate water level sensor. Squeeze catches

together and pull up to remove sensor.

13. Separate probes from housing and wash all

surfaces with ice machine scale remover solution.

Rinse and return probes to holder.

14. Create a solution of sanitizer. Mix 8 ounces of

NuCalgon IMS II and 5 gallons of 105-115 degree

F. potable water to create a 200 ppm active

quaternary solution.

15. Thoroughly wash all surfaces of the ice thickness

sensor, water level sensor, curtain and water

distributor with the sanitizer solution.

16. Wash all interior surfaces of the freezing

compartment, including evaporator cover and right

side panel liner with the sanitizer solution.

17. Return water level sensor, ice thickness sensor,

water distributors and curtains to their normal

positions. Be sure water level sensor and ice

thickness sensor are completely dry.

18. Push and release the Clean button. The yellow

Clean light will blink and the display will show C.

The machine will go through a harvest cycle, drain

the reservoir and begin to refill it.

19. Observe code display, when it blinks the

characters “Ad1” immediately go to the next step.

20. Pour the sanitizing solution into the reservoir until

it is full. The unit will circulate the sanitizer, then

drain and flush it. This will take 35 minutes, then

the machine will stop and the display will show O.

21. Return all panels and covers removed to their

original positions.

22. Push and release the On button to resume ice

making.

Ice Storage Bin
Remove and discard all ice. Mix a solution of

Scotsman Clear 1 ice machine scale remover and

wash all interior surfaces of the ice storage bin to

remove any mineral scale build up. Pour excess

cleaner solution into the bin’s drain.

Mix a solution of sanitizer and thoroughly wash all

interior surfaces of the ice storage bin.

Inspect Orifice Holes

Release probes by pushing in on white buttons and

pulling probe down out of holder. The white holder is

an insulator and must be clean for proper operation.

Holder

Squeeze tabs together, slide out until it stops, then lift

to remove.