Technical service diagnosis csw45 – Scotsman CSW45 User Manual

Page 18

Advertising
background image

Technical Service Diagnosis

CSW45

July 1999

Page 18

Symptom

Possible Cause

Probable Correction

Unit Off

No power to unit

Plug unit it

Reset circuit breaker or replace
fuse

Unit switched off

Check control switch

Ice level control keeping unit off

Room colder than 55

o

F., increase

heat

Ice on sensor tube - remove it

Transformer Open

Check/replace transformer

Control board failed

Switch unit to Clean, note if all
valves and motors are switched
on for 5 seconds each one after
another. If not, replace the board.

Unit runs, makes no ice

No water to unit

Check/restore water supply

Check water valve

Pump does not run

Check connection from control
box to pump

Check/replace pump

Unit overheating

Check for dirty condenser

Check fan blade and motor

Air flow blocked, check for air
obstruction

Compressor does not run

Check compressor relay

Check compressor windings

Low on refrigerant

Install service ports, weigh out
charge, If low, locate and repair
leak, replace drier evacuate to
300 microns and weigh in
nameplate charge*

Hot gas valve leaking thru

Check/replace hot gas valve

* If the system has been running in a vacuum AND the leak is found to be on the LOW side, repair the leak
AND replace the compressor.