Sundance SMT381 2004 User Manual

Page 62

Advertising
background image

Figure 47. Components Used to Connect the SMT381 to the SMT338-VP.

•

First fit two Nylon screws (M2 x 10), pointing out (the head of the screws on

the bottom side of the SMT338-VP).

•

Then fit four M2 nuts on each screw.

•

Place the SMT338-VP on the second TIM site (TIM 1 is for the Host) of a

Sundance carrier (like the SMT310Q)

•

Fit the two metal pillars to the TIM mounting holes to give the SMT338-VP

3.3V from the carrier.

•

Place the SMT381-VP on top of the SMT338-VP and make sure that both

modules fit firmly (the SMT381 does not need 3.3V of it’s mounting hole).

•

Fit two M2 nuts on the Nylon screws and two M3x4 screws in the 3.3V pillars.

•

Connect ComPort3 of the SMT381-VP to an available ComPort on the Host

module (eg ComPort 0).