Constraint file signal names – Sundance SMT407 User Manual
Page 21

Version 1.0.0
Page 21 of 38
SMT407 User Manual
Constraint File Signal Names
According to the
SUNDANCE SHB specification
, 5 Byte-interfaces (from 0 to 4) can
be implemented on the 60 pins of a SHB connector. Each Byte interface has its own
CLK, WEN, REQ and ACK.
The signal names going from the FPGA to the SHB connector use the configuration
of 2 SDB interfaces.
So, when in Half Word configuration:
• 16-bit data D(0 to 15)
• CLK0 is borrowed from Byte configuration 0, WEN1, REQ1 and ACK1 are
borrowed from Byte configuration 1 to make configuration SDBA control
signals and
• CLK3 is borrowed from Byte configuration 3, WEN4, REQ4 ACK4 are
borrowed from Byte configuration 4 to make configuration SDBB control
signals.
The SHB connectors are J3 and JA3. (See
Figure 10: SMT407 Components placement-
Top view and See
Figure 11: SMT407 Components placement-Bottom view)
Please refer to section SHB Headers for more information.