Control from the rc-601mkii, Control from the rs-232c interface, External control – Teac CD-601MKII User Manual

Page 26: Setting operation on the cd player, Setting the baud rate

Advertising
background image

26

TASCAM CD-601MKII

EXTERNAL CONTROL

Control from the RC-601MKII

Functions are added to the CD player and the CD player
becomes easier to user by using the Remote Control Unit
RC-601MKII (sold separately).

Expanded and additional functions by the
RC-601MKII

• Time chart/index search using the numeric keys

• Search using the jog/search dial

• End check function that allows you to listen to the end of

tracks

• 1 tune repeat, all tunes repeat, program repeat, repeat

playback between A and B

• Max. 10 cue points can be set to a single disc.

• Flash start function using 10 cue points

• Cue point settings for 500 discs can be stored to

memory.

• Playback between A and B using MEMO points and

confirmation playback of points are possible.

• The monitor outputs of up to four CD-601MKII can

be connected to RC-601MKII and monitored on
headphones.

Setting operation on the CD player

Operation on the CD player can be selected between
enabled and disabled when the RC-601MKII is connected.

Set enable/disable using menu No. 17 (“RMT”).

R_L (REMOTE + LOCAL, default): Operation of the CD

player is possible on both the RC-601MKII and the CD
player.

R (REMOTE): Operation of the CD player is possible on

only the RC-601MKII.

Operation of the CD player except the OPEN/CLOSE

key is disabled.

When the RC-601MKII is not connected, operation of the
CD player is enabled regardless of the setting of this item.

Control from the RS-232C interface

The CD player can be controlled on the serial interface
from a PC or other external equipment using the REMOTE
(SERIAL)
terminal (15-pin D-Sub connector, RS-232C-
compliant) on the rear panel. For details, contact us.

Pin Arrangement

Pin No. Signal Name IN/OUT

1

SHIELD

–

Shielded (shell ground)

2

RX

IN

Receive data

3

(Reserved)

–

Reserved

4

(Reserved)

–

Reserved

5

(Reserved)

–

Reserved

6

GND

–

Ground

7

(Reserved)

–

Reserved

8

(Reserved)

–

Reserved

9

TX

OUT

Send data

10

(Reserved)

–

Reserved

11

(Reserved)

–

Reserved

12

(Reserved)

–

Reserved

13

(Reserved)

–

Reserved

14

(Reserved)

–

Reserved

15

(Reserved)

–

Reserved

Setting the baud rate

When the REMOTE (SERIAL) terminal is used to control
the CD player, select the appropriate baud rate from the
following using menu No. 23 (“RS232C”).

B-0: (default when RC-601MKII is connected)

B-1: 1,200

bps

B-2: 2,400

bps

B-3: 4,800

bps

B-4: 9,600

bps

B-5: 19,200

bps

B-6: 38,400

bps

1
9

8

15

CD-601MKII_Eng.indd 26

3/26/2005 7:40:02 PM

Advertising