This unit has an automatic power saving function.
So, by default, the unit will enter automatic power saving mode
automatically after 30 minutes elapse without any locked input
signal. (Power consumption in this standby mode is 0.5 W or less.)

o

The automatic power saving function is on when the unit is
shipped from the factory.

Checking the automatic power saving setting

If automatic power saving is off, all the input indicators will light
temporarily when the unit is turned on.

Setting the automatic power saving function

When the unit is on, press and hold the ¤ button for five sec-
onds until all the input indicators light or turn off.

No indicators lit: APS on
All indicators lit: APS off

Automatic power saving (APS) function

Upconversion function

When using a digital input (USB*, OPTICAL or COAXIAL), the
upconversion function can be used.
*DSD audio will not be upconverted.

Press and hold the source button for about five seconds until the
sampling frequency indicators light as follows.

44.1kHz and 48kHz indicators lit: Upconversion off
44.1kHz to 96kHz indicators lit: Upconversion setting 1
44.1kHz to192kHz indicators lit: Upconversion setting 2

Input frequency and frequency after upconversion

Input frequency

Setting 1

Setting 2

44.1 kHz

88.2 kHz

176.4 kHz

48 kHz

96 kHz

192 kHz

88.2 kHz

No upconversion

176.4 kHz

96 kHz

No upconversion

192 kHz

o

Frequencies of 176.4 kHz and higher will not be upconverted
when input.

Sampling frequency indicators during upconversion
When upconversion is in use, two sampling frequency indicators
will light.
The left one shows the input frequency and the right one shows
the frequency after upconversion.