17 – specifications—messages and troubleshooting – Teac DM-24 User Manual

Page 129

Advertising
background image

17 – Specifications—Messages and troubleshooting

TASCAM DM-24 Reference Manual

129

✖

Can’t do MIDI Bulk Load
with timecode running

Shown if an attempt is made to load Bulk Data with timecode running (“Bulk
transfer of data to the DM-24” on page 96)

✔

Can’t assign fader grouping layer.

Shown when an invalid fader grouping is attempted (“Grouping layers” on
page 71)
.

✔

Can’t assign mute grouping layer.

Shown when an invalid mute grouping is attempted (“Grouping layers” on
page 71)
.

✔

Can’t Dump MIDI Sys Ex data.
SysEx filter is set in MIDI/MC
[SETUP] screen]
Press ENTER to continue.

Shown if a MIDI filter has been set up preventing MIDI System Exclusive trans-
mission (“MIDI filtering” on page 84) and an attempt is made to dump data.

●

Can’t Recall COMP Libraryxxx.

The compressor library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry) — “Library functions” on page 99

●

Can’t Recall Effect U1-xxx.

The user effect 1 library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry) — “Library functions” on page 99

●

Can’t Recall EQ Libraryxxx

The EQ library entry xxx cannot be recalled as it does not exist (no data has
been written to that library entry)—“Library functions” on page 99

●

Can’t recall GATE/EXP Libraryxxx.

The gate/expander library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry (“Library functions” on page 99)

●

Can’t recall Snapshotxxx.

The snapshot xxx cannot be recalled as it does not exist (no data has been writ-
ten to that library entry)

●

Can’t recall to Chxx.
GATE/EXP is not inserted.

An attempt has been made to load gate/expander settings from the library to a
module where a gate or expander has not been inserted (“Library functions” on
page 99)
.

✔

Can’t select dual-line
Different Fs mode
Press ENTER key to continue.

An attempt has been made to select dual-line transmission in normal sampling
frequency mode (must be “normal”)— “High sampling frequency” on page 112.

✔

Can’t select dual-line
Different Fs mode
Press ENTER to continue.

An attempt is made to select the dual-line format in normal sampling frequency
mode (“High sampling frequency” on page 112).

●

Can’t STORE Automation Bank01.

Shown if there is a problem overwriting a protected memory bank (automation)

✖

Cascade connection broken!
Press ENTER to continue.

Shown on cascade master when an existing cascade connection has become
disconnected or is otherwise inoperative (“Cascade card” on page 119).

✔

Ch parameters Setup?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when a global screen has been used to make changes to a range of
channels at one time (for instance aux sends, digital delay, etc.), (“Module oper-
ations” on page 49
.)

●

CH x is already inserted.

An attempt has been made to assign a second insert loop to a channel which
has already had an insert loop assigned to it (“Assignable returns” on page 36).

✔

Clear all fader grouping layers ?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when the on-screen CLEAR button has been pressed to clear all fader
groups (“Grouping layers” on page 71).

✔

Clear all muting grouping layers ?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when the on-screen CLEAR button has been pressed to clear all mute
groups (“Grouping” on page 69).

✔

Clear Current Automation Event Data?
Press ENTER to confirm,
or a cursor key to cancel.

Shown in automation, when the current data is to be cleared (using soft key 2)

Action

Message

Explanation

Advertising