Tone Commander NT1B-300 Rack Installation Instructions

Page 4

13-280113 Rev. B

Cable Connections

Back Panel Connectors

All rack S/T and U ribbon connectors are female; male connectors are required on the cable
ends.

U lnterface

Connect each U interface pair from the network interface block into the appropriate position on the 50-pin U
interface connector on the rack rear panel. See Table 2 for connector pinouts. The rack uses self-locking
connectors; to remove a cable, use a small tool to press in the tabs on the ends of the connector.

S/T Interface

The S/T interface for each terminal can be connected one of two ways:

1. Modular jacks on the front of the NT1B-300TC units – for terminal equipment or patch panel connection

via an 8-position modular phone cord. Connecting cords must be Category 3 or higher with T568 A or
T568 B wiring. See Table 1 and the figure below for jack pinout.

Two parallel-wired jacks are provided on each NT1, for two terminals connected in a multipoint
arrangement.

2. 50-pin ribbon connectors on the rack back panel – for terminal equipment connection via a punch-down

block. See Table 2 for connector pinouts.

Connect the terminal wall jacks to 4-pair cables as shown in Table 1. Punch down the cables to the cross-
connect blocks in the order shown in Table 1. Note that pairs 1-2 and 3-6 for T568A jacks are reversed
from T568B jacks.

Wire Color

Pin #

Signal

T568 A

T568 B

*

(AT&T)

5

Tx-

WHT-BLU

WHT-BLU

4

Tx+

BLU

BLU

1

unused

WHT-GRN

WHT-ORN

2

unused

GRN

ORN

3

Rx+

WHT-ORN

WHT-GRN

6

Rx-

ORN

GRN

7

-48V

WHT-BRN

WHT-BRN

8

-48VRTN

BRN

BRN

Table 1 – Modular Jack Pinout