Thermo Technologies SMT 400 User Manual

Page 22

Advertising
background image

21

3.8

CALIBRATION TRIMMING SCREEN

1

Pressing and holding the

key for 10 seconds, reveals the calibration

trimming screen.

2

Use the

keys to select which sensor temperature value you want to

trim.

3

To alter the value of trimming, simply press the

or

key and the

temperature reading will change accordingly.

SECTION 4 - FAULT FINDING

Problem:

Nothing happens when the unit is powered-up.

Cause/Remedy:

One of the fuses could be blown - check and replace if
necessary (refer to specifications for values). If the fuses blow
again, contact the agency where the unit was purchased.

Problem:

The temperature display is fluctuating.

Cause/Remedy:

One of the sensor connectors may be loose, or a sensor may
be too close to a mains cable. Check sensor connectors and
re-route cables as necessary.

Problem:

The display screen is too dark or faint.

Cause/Remedy:

Adjust the display contrast to suit - see ‘Display Contrast’
(Section 3.2).

Problem:

The System Alarm light is flashing.

Cause/Remedy:

This indicates a system alarm warning, which may be caused
by a sensor fault or if the TM setting is exceeded (see Section
3.4 SET SCREEN 1). A sensor will show fault if it measures a
temperature above +99°C or below -15°C, this will not
damage the sensor and the fault condition will clear when the
sensor is operated within this range.