SECTION 5 SPECIFICATIONS

ELECTRICAL:
Supply Voltage:

220-240V AC Single Phase

Fuses:

1 X 6.3A Slow Blow, 1 X 1A Quick Blow.

Relay Outputs:

Pump 1 Relay:

2A single pole - output live
when energized (max. 400W).

Pump 3 Relay:

2A single pole - output live
when energized (max. 400W).

Pump 3 Relay:

2A single pole - output live
when energized (max. 400W).

A1 Relay:

2A changeover 3 pin isolated (volt free
contacts) can be used for mains voltage
only.

(max. 400W).

A2 Relay:

2A single pole - output live
when energized (max. 400W).

The Total Output Current must not exceed 5.5A

MECHANICAL:
Dimensions:

width: 165mm
height: 100mm
depth: 85mm
weight: SMT 400 0.92Kg
Sensor: (each) 0.1Kg

Box Material:

Plastic (ABS)

Front Panel:

Reverse printed

Display:

Large LCD supertwist graphics

SENSORS:
Type:

Platinum PT100

Wire:

3- wire compensated

Cable Length:

1 X Collector sensor 25m
1 X Tank sensor 5m
1 X Return sensor 5m

Battery:

9V PP3 Rechargeable

PARTS LIST

SMT 400 Control Unit

C0128

Collector Sensor Pocket (TC)

A0477

25m Collector Sensor (TC) A0741

Return Sensor Pocket (TR)

A0683

10m Collector Sensor (TC) A7143

Tank Sensor Pocket (TT)

A0332

0.5m Return Sensor (TR)

A0740

Sensor Extender 10m

A6911

5m Return Sensor (TR)

A7141

Sensor Extender 20m

A6921

5m Tank 1 Sensor (TT1)

A0742

Sensor Extender 50m

A6951

0.25m Tank 2 Sensor (TT2) A7140