Venting installation instructions – Desa (V)KC36NE Series User Manual

Page 12

Advertising
background image

www.desatech.com

116238-01E

12

VENTING INSTALLATION

INSTRUCTIONS

Continued

Figure 13 - Typical Horizontal

Termination Cap Mounting with

Additional Siding Standoff Installed

Siding Standoff

Screws

High Wind
Termination

Apply
Mastic to
Outside
Edge of
Standoff

Exterior Wall with Vinyl Siding

10

3

/

4

" x 10

3

/

4

"

Framed Opening

Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall

Minimum Pipe
Overlap 1

1

/

4

"

Wall
Firestop

Direct-Vent
Pipe

Horizontal Termination Configurations

Figures 14 through 18 show different configura-

tions and alternatives for venting with horizontal

termination. Each figure includes a chart with

critical minimum and maximum dimensions which

MUST be met. IMPORTANT: If using a venting

configuration of only horizontal venting with no

vertical run, a 1/4" rise for every 12" of run toward

the termination is required.

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

WARNING: Never run vent

downward as this may cause

excessive temperatures which

could cause a fire. Operation of

improperly installed and main-

tained venting system could

result in serious injury, property

damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

• Installation using cabinet surrounds

• Through the wall using round or square termina-

tion (up to 12" horizontal pipe)

• NOT FOR CORNER INSTALLATION

Horizontal
High Wind
Square
Termination

Wall Firestop

45° Elbow

Figure 14 - Horizontal Termination

Configuration for Square or Round

Terminations

45° Elbow

Wall
Firestop

Horizontal
Round
Termination

Exterior Portion of
Wall Firestop (Round
Termination Only)

Adjustable
Pipe 12" Max.

Round Termination

Square Termination

Vertical (V)

Horizontal (H)

32

3

/

4

" min.

17" max.

* If installing this fireplace at altitudes of
4000 feet and above, it is recommended
that an additional vertical height of 6" be
added to the vent system.

Advertising
This manual is related to the following products: