pRESSURE TESTING FIREpLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 33,

page 23).

2. Open propane/LP supply tank valve for

propane/LP fireplace or main gas valve

located on or near gas meter for natural gas

fireplace.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 34 or 35 on page 23).

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct

all leaks at once.

5. Light fireplace (see Operating Fireplace, page

28). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Ap-

pliance, page 28).Removing/Replacing Glass

Door.

CAUTION: Do not operate

this fireplace with a broken glass

door panel or without the glass

door panel securely in place.

For replacement part informa-

tion see Replacement Parts,

page 34.

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass. Do

not remove if glass is hot. Keep

children and pets away from

glass.

WARNING: If fireplace has

been running, turn off and un-

plug fireplace. Let cool before re-

moving glass door or louvers.

FIREPLACE

INSTALLATION

Continued

Removing Louver Panels

Remove the top and bottom louver panels by si-

multaneously pulling both top end spring latches

towards the center of the appliance until they are

disengaged from the locating holes (see Figure 36).

Repeat for bottom spring latches and pull the lou-

vers outward. To install or replace items removed,

simply reverse the procedures above.

Figure 36 - Removing Louver Panel

Louver
Panel

Spring
Latch

Removing Glass Door

If replacement of glass is necessary, the entire

assembly, glass and frame, must be replaced. If

glass is broken, wear gloves and tape the remaining

fragments onto the frame.

1. Remove screen assembly by pushing the rod

either left or right and then down and forward

to remove screen/rod assembly from the fire-

box. Set assembly aside.

2. Lift up on latches to unlock. There are two on

top of firebox and two below firebox that hold

glass door in place (see Figure 37).

3. While holding glass door to prevent it from

falling and causing injury, remove the five

screws from the hinge located on the left side

of door frame assembly (see Figure 37).

Lock

Unlock

Glass Frame
Assembly

Screw

Figure 37 - Removing/Replacing Glass

Door

Hinge

Latch