Fireplace installation – Desa (V)KC36NE Series User Manual

Page 21

Advertising
background image

www.desatech.com

116238-01E

21

7. Check to make sure that the power cord is com-

pletely clear of the blower wheel and that there

are no other foreign objects in blower wheel. Also

double check all wire leads and make sure wire

routing is not pinched or in a precarious position.

Correct accordingly.

8. Turn on power to duplex outlet if previously

turned off per the warning in column 1,

page 19.

9. Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed control

knob is in the ON position and the thermal switch

senses temperature after the fireplace begins to

heat up. The blower speed can be adjusted by

rotating the control knob. To turn off, turn knob

fully counterclockwise until it clicks off. If the

blower is ON and has been running with the

fireplace operating, the blower will continue to

run for a short time after the fireplace has been

turned off. As the thermal switch cools down, the

blower shuts down automatically.

11. Peel off the backing paper and stick the sup-

plied wiring diagram decal on the firebox bot-

tom approximately 12" in front of the blower

(see Figure 27, page 20).

Blower Wiring Diagram

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and dan-

gerous operation. Verify proper

operation after servicing.

FIREPLACE

INSTALLATION

Continued

Figure 29 - Blower Wiring Diagram for

Thermostat-Controlled Models

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

INSTALLING GAS pIpING TO
FIREpLACE LOCATION

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: For propane/LP

units, never connect fireplace di-

rectly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between

the fireplace and propane/LP

supply.

WARNING: For natural gas,

never connect heater to private

(non-utility) gas wells. This gas

is commonly known as wellhead

gas.

Installation Items Needed

Before installing fireplace, make sure you have

the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas connector

(if allowed by local codes)

* A CSA design-certified equipment shutoff

valve with 1/8" NPT tap is an acceptable alterna-

tive to test gauge connection. Purchase the CSA

design-certified equipment shutoff valve from

your retailer.

For propane/LP connection only, the installer must

supply an external regulator. The external regula-

tor will reduce incoming gas pressure. You must

reduce incoming gas pressure to between 11" and

14" of water. If you do not reduce incoming gas

pressure, fireplace regulator damage could occur.

Install external regulator with the vent pointing

down as shown in Figure 30, page 22. Pointing the

vent down protects it from freezing rain or sleet.